microfluidic dynamic qpcr arrays 48.48 chip format Search Results


95
fluidigm dynamic array ifc chip
Dynamic Array Ifc Chip, supplied by fluidigm, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/48%2E48+Dynamic+Array+IFC+for+Genotyping/pmc05396199-167-3-7
Average 95 stars, based on 1 article reviews
dynamic array ifc chip - by Bioz Stars, 2026-10
95/100 stars
  Buy from Supplier

96
fluidigm microfluidic chips
Microfluidic Chips, supplied by fluidigm, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/Biomark/pmc10865169-69-22-24
Average 96 stars, based on 1 article reviews
microfluidic chips - by Bioz Stars, 2026-10
96/100 stars
  Buy from Supplier

93
fluidigm access array microfluidics chips
Access Array Microfluidics Chips, supplied by fluidigm, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/Access+Array/med_rxiv__2020__11__11__20226845-40-9-13
Average 93 stars, based on 1 article reviews
access array microfluidics chips - by Bioz Stars, 2026-10
93/100 stars
  Buy from Supplier

94
fluidigm dynamic array ifc chips
Dynamic Array Ifc Chips, supplied by fluidigm, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/48%2E48+Dynamic+Array+IFC+for+Gene+Expression/pmc04417935-275-12-16
Average 94 stars, based on 1 article reviews
dynamic array ifc chips - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

99
Illumina Inc miseq sequencing
FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon <t>sequencing</t> (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.
Miseq Sequencing, supplied by Illumina Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/MiSeq+System/pm29755444-9-20-22
Average 99 stars, based on 1 article reviews
miseq sequencing - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

99
Bio-Rad low rox
FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon <t>sequencing</t> (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.
Low Rox, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/SsoFast+Eva+Green+Supermix+With+Low+ROX/pm40623988-264-20-22
Average 99 stars, based on 1 article reviews
low rox - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

94
Integrated DNA Technologies gene synthesis
FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon <t>sequencing</t> (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.
Gene Synthesis, supplied by Integrated DNA Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/Gene+Synthesis/custom%40gene-synthesis%4017634136
Average 94 stars, based on 1 article reviews
gene synthesis - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

99
Bio-Rad ssofast evagreen supermix
FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon <t>sequencing</t> (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.
Ssofast Evagreen Supermix, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/SsoFast+Eva+Green+Supermix/pm40623988-264-16-22
Average 99 stars, based on 1 article reviews
ssofast evagreen supermix - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

96
fluidigm c1 platform
FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon <t>sequencing</t> (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.
C1 Platform, supplied by fluidigm, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/microfluidic+dynamic+qpcr+arrays+48%2E48+chip+format/C1/pmc07570277-136-14-13
Average 96 stars, based on 1 article reviews
c1 platform - by Bioz Stars, 2026-10
96/100 stars
  Buy from Supplier

Image Search Results


FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon sequencing (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.

Journal: Frontiers in microbiology

Article Title: Microfluidic PCR Amplification and MiSeq Amplicon Sequencing Techniques for High-Throughput Detection and Genotyping of Human Pathogenic RNA Viruses in Human Feces, Sewage, and Oysters.

doi: 10.3389/fmicb.2018.00830

Figure Lengend Snippet: FIGURE 1 | Pipeline of microfluidic nested PCR followed by MiSeq amplicon sequencing (MFnPCR–MiSeq). Purification of PCR amplicons was carried out with the NucleoSpin Gel and PCR Clean-up Kit. Amplification by the first-round and nested PCR was performed on a 48.48 Access Array (AA) chip in a BioMark HD reader, while the third PCR for addition of a sample-specific tag and Illumina adapter was run in 96-well PCR plates on a conventional thermal cycler.

Article Snippet: Microfluidic nested PCR was carried out on a 48.48 Access Array chip, and the amplicons were recovered and used for MiSeq sequencing (Illumina, Tokyo, Japan); genotyping was conducted by homology searching and phylogenetic analysis of the obtained sequence reads.

Techniques: Nested PCR, Amplification, Sequencing

FIGURE 2 | Detection of serially diluted virus samples by microfluidic nested PCR followed by MiSeq amplicon sequencing. Plasmid DNA and cDNA samples containing target regions of each virus were mixed at equimolar concentrations and diluted to 104–100 copies/µL. The mixtures were subjected to the first round of MF-PCR, and the amplicon was collected and used for MFnPCR with 20 oligonucleotide primer sets for detection of 11 viruses (i.e., AiV; AsV; EV; NoV GI, GII, and GIV; HAV; HEV; RV; SaV; and HPV). CT values determined in the nested MF PCR are shown as a heat map. Amplicon size represents the size of a PCR amplicon without an Illumina tag sequence.

Journal: Frontiers in microbiology

Article Title: Microfluidic PCR Amplification and MiSeq Amplicon Sequencing Techniques for High-Throughput Detection and Genotyping of Human Pathogenic RNA Viruses in Human Feces, Sewage, and Oysters.

doi: 10.3389/fmicb.2018.00830

Figure Lengend Snippet: FIGURE 2 | Detection of serially diluted virus samples by microfluidic nested PCR followed by MiSeq amplicon sequencing. Plasmid DNA and cDNA samples containing target regions of each virus were mixed at equimolar concentrations and diluted to 104–100 copies/µL. The mixtures were subjected to the first round of MF-PCR, and the amplicon was collected and used for MFnPCR with 20 oligonucleotide primer sets for detection of 11 viruses (i.e., AiV; AsV; EV; NoV GI, GII, and GIV; HAV; HEV; RV; SaV; and HPV). CT values determined in the nested MF PCR are shown as a heat map. Amplicon size represents the size of a PCR amplicon without an Illumina tag sequence.

Article Snippet: Microfluidic nested PCR was carried out on a 48.48 Access Array chip, and the amplicons were recovered and used for MiSeq sequencing (Illumina, Tokyo, Japan); genotyping was conducted by homology searching and phylogenetic analysis of the obtained sequence reads.

Techniques: Virus, Nested PCR, Amplification, Sequencing, Plasmid Preparation

FIGURE 3 | Detection and typing of viruses in samples of human feces, sewage, and contaminated oysters. The number of reads obtained by MiSeq sequencing is shown at the top of the panel, and relative abundance of the sequence reads affiliated with a specific genotype of viruses is shown in the figure. The identified genotypes are indicated in the bars.

Journal: Frontiers in microbiology

Article Title: Microfluidic PCR Amplification and MiSeq Amplicon Sequencing Techniques for High-Throughput Detection and Genotyping of Human Pathogenic RNA Viruses in Human Feces, Sewage, and Oysters.

doi: 10.3389/fmicb.2018.00830

Figure Lengend Snippet: FIGURE 3 | Detection and typing of viruses in samples of human feces, sewage, and contaminated oysters. The number of reads obtained by MiSeq sequencing is shown at the top of the panel, and relative abundance of the sequence reads affiliated with a specific genotype of viruses is shown in the figure. The identified genotypes are indicated in the bars.

Article Snippet: Microfluidic nested PCR was carried out on a 48.48 Access Array chip, and the amplicons were recovered and used for MiSeq sequencing (Illumina, Tokyo, Japan); genotyping was conducted by homology searching and phylogenetic analysis of the obtained sequence reads.

Techniques: Sequencing